All Seals is a recognized leading converter of high qualityenclosure gaskets and seals. Our company's reputation for excellence has been built on our ability to provide our valued customers with the most effective designing, engineering and converting solutions to meet their most demanding applications. Our main objective is to continuously exceed our customer's expectations by providing them with high performance gaskets and sealing products, competitive pricing, on-time delivery and exceptional customer service.
All Seals has experience in the providing of custom electrical enclosure gaskets and seals for a wide range of industries and applications. Our primary focus is on the fabrication of electrical enclosure gaskets, NEMA enclosure gaskets, IP standard gaskets, and enclosure door gasketsdesigned for indoor and outdoor electronic sealing applications. Enclosure gaskets are positioned inside metal or plastic enclosure boxes, cabinets, doors and covers providing a sealing barrier between the housing and the cover of the electrical enclosure. The design and function of the enclosure can differ depending on material, size and factors needed for the application, for instance dustproof, waterproof, exposure to water and ice, chemicals, oil and UV. The general performance required such as dust sealing, wash-down protection, or submersion will also determine the best material for the enclosure gasket. Enclosure gaskets and seals are typically produced from weatherproof and UL 94 rated closed cell sponge rubber and silicone sponge gasket materials. The material's closed cell construction creates an ideal weatherproofing gasket for electrical enclosures and other electronic sealing applications exposed to outdoor environmental conditions.
NEMA Enclosure Gaskets(NEMA Ratings & IP Standards)
NEMA Ratings & IP Equivalent Conversion Chart
NEMA Rating
IP
Equivalent
NEMA Definitions
IP Definitions
IP Numerical Protection Levels
1
IP10
Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment & to provide a degree of protection against falling dirt.
1 = Protected against solid foreign objects of 50mm in diameter & greater
0 = Not Protected
2
IP11
Enclosures constructed for indoor used to provide a degree of protection to personnel against incidental contact with the enclosed equipment, to provide a degree of protection against falling dirt, & to provide a degree of protection against dripping & light splashing of liquids.
1 = Protected against solid foreign objects of 50mm in diameter & greater
1 = Protected against vertically falling water drops
3
IP54
Enclosures constructed for either indoor or outdoor used to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to proved a degree of protection against falling dirt, rain, sleet, snow, & windblown dust; & that will undamaged by external formation of ice on the enclosure.
5 = Protected against dust - Limited to ingress (no harmful deposit)
4 = Protected against water sprayed from all directions - Limited to ingress permitted.
3R
IP14
Enclosures constructed for either indoor or outdoor used to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, & snow; & that will be undamaged by external formation of ice on the enclosure.
1 = Protected against vertically falling water drops
4 = Protected against water sprayed from all directions - Limited to ingress permitted.
3S
IP54
Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, & windblown dust; & in which the external mechanism(s) remain operable when ice laden.
5 = Protected against dust - Limited to ingress (no harmful deposit)
4 = Protected against water sprayed from all directions - Limited to ingress permitted.
4
IP 56
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, & hose-directed water; & that will be undamaged by the external formation of ice on the enclosure.
5 = Protected against dust - Limited to ingress (no harmful deposit)
6 = Protected against strong jets of water from all directions - Limited to ingress permitted.
4X
IP56
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, & corrosion; & that will be undamaged by the external formation of ice on the enclosure.
5 = Protected against dust - Limited to ingress (no harmful deposit)
6 = Protected against strong jets of water from all directions - Limited to ingress permitted.
5
IP52
Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against settling airborne dust, lint, fibers, & flyings; & to provide a degree of protection against dripping & light splashing of liquids.
5 = Protected against dust - Limited to ingress (no harmful deposit)
2 = Protected against direct sprays of water up to 15° from the vertical.
6
IP67
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water & the entry of water during occasional temporary submersion at a limited depth; & that will be undamaged by the external formation of ice on the enclosure.
6 = Totally protected against dust
7 = Protected against the effects of temporary immersion between 15cm & 1m. Duration of test 30 minutes.
6P
IP67
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to the personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water & the entry of water during prolonged submersion at a limited depth; & that will be undamaged by the external formation of ice on the enclosure.
6 = Totally protected against dust
7 = Protected against the effects of temporary immersion between 15cm & 1m. Duration of test 30 minutes.
12 & 12K
IP52
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, & flying; & against dripping & light splashing of liquids.
5 = Protected against dust - Limited to ingress (no harmful deposit)
2 = Protected against direct sprays of water up to 15° from the vertical.
13
IP54
Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, & flyings; & against the spraying, splashing, & seepage of water, oil, & noncorrosive coolants.
5 = Protected against dust - Limited to ingress (no harmful deposit)
4 = Protected against water sprayed from all directions - Limited to ingress permitted.
N/A
IP65
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, & flying; & against dripping & light splashing of liquids.
6 = Totally protected against dust
5 = Protected against water projected from a nozzle.
N/A
IP66
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, & flying; & against dripping & light splashing of liquids.
6 = Totally protected against dust
6 = Protected against strong jets of water from all directions - Limited to ingress permitted.